Quality Management
We’re committed to keep High Quality & High Standards for all customer on quality control. From ISO:9001,ISO:14001,ISO:45001,ISO:50001 to standard CNAS laboratory, our factory has top level manufacturing and testing facilities.meanwhile,from CE,ENEC,,CB,ETL,DLC,SAA to comprehensive quality control process, from the IQC of raw material to OQC of the completed products, LEPOWER is checking the product quality in every step,controlling the general failure rate in 0.2%.
Laboratory Overview
Capable of testing 12 items of "LED module" series products
-
IES test room
Uses:Test the curve distribution of the lamps in all directions of the space to obtain the light distribution curve, which can detect whether the light effect of the lamps and the light distribution curve meet the requirements. 123
-
Integrating sphere test equipment
Uses: Luminous flux, CCT, CRI, Luminous efficiency and other indicators.
-
Constant temperature and humidity test equipment
Uses: low temperature -40 ℃, high temperature +100 ℃, relative humidity 85%, RH ± 5%, they can test and determine parameters and performancethe of products and materials after high temperature, low temperature, humidity or constant temperature environment
-
Oven
Uses:50-100℃, the constant high temperature environment enables our lighting and aging test to be fully executed, fully testing the high temperature life of lamps and lanterns. Thermal shock test equipment
-
Thermal shock test equipment
Uses: low temperature -40 ℃, high temperature +100 ℃, adaptability test for storage, transportation and use in environments with sharp temperature changes. Detect chemical changes or physical damage caused by thermal expansion and contraction of products
-
Vibration test equipment
Uses: Frequency 5-200Hz, sweep frequency 5-200Hz. The vibrating platform simulates the movement of transport, allowing our products and packaging to withstand the worst road conditions.
-
Salt spray test equipment
Uses:Application: Temperature 30-35℃, humidity ≥85%, RH, PH6.5-7.2, sodium chloride mist solution can effectively perform the surface treatment technology level and corrosion test of our products.
-